APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets

Delivery and Shipping

Pengiriman & Proses

Proses Urutan

  • Bisnis yang sama - hari untuk perintah ditempatkan sebelum 3 PM (GMT), kecuali dalam kasus langka ketika dapat mengambil 1 hari bisnis tambahan.
  • Barang yang lebih besar atau spesialis memerlukan hingga 3 hari bisnis untuk memproses.

Opsi Pengiriman

  • Royal Mail 48
    • Perintah bebas lebih dari £20
    • £2.99 pada perintah di bawah £20
    • Pengiriman dalam 2-3 hari bisnis
  • Dilacak 24 (Next-Day)- £4,99
  • Standar (Item Spesialis & Besar)
    • Perintah bebas lebih dari £20
    • £6.99 pada perintah di bawah £20
    • Pengiriman dalam 2-14 hari bisnis (biasanya sekitar 7 hari)
    • Proses mungkin memakan waktu sampai 3 hari bisnis
  • Internasional
    • Kami kapal di seluruh dunia. Opsi pengiriman dan perkiraan jangka waktu bagi negara Anda tersedia di checkout.
    • Bea Cukai, tugas, dan pajak impor adalah tanggung jawabmu.

Anda akan menerima pelacakan rincian segera setelah kapal pesanan Anda [melacak pesanan Anda di sini]. Untuk rincian penuh, silahkan lihat kami [Pengiriman Kebijakan].

Free Returns

Buy with confidence. If you're not completely satisfied with your purchase, you can return eligible items within 60 days of delivery. Products must be unused, in their original condition and packaging, and accompanied by proof of purchase.

No hassle if there's a problem. If your item arrives damaged, defective, or incorrect, simply get in touch and we'll work quickly to make it right.

Simple returns, fast refunds. Once your return has been received and inspected, approved refunds are issued to your original payment method. View our full Refund Policy for complete details and exclusions.

APC NetShelter Rack PDU Advanced (11K Series) provides reliable power distribution to IT equipment within server and/or networking racks in ZeroU form. PDU level power metering provides power visibility and notification of potential overload. 50 percent of outlets on model are designed as 4 in 1 combination outlets which can be used as either C13, C19, C15, or C21 to provide unparalleled deployment flexibility. Outlets on the PDUs are color coded and labeled by breaker. Live Swap the NMC3 to minimize downtime in the unlikely event of an NMC power event. The rack PDU integrates with EcoStruxure IT through an NMC3 and can be accessed and configured via web, SNMP, and command line interface (CLI). Rated to operate up to 60 C (140 F) at full load ensures reliability and availability even in today s high density deployments. One gigabit Ethernet/network port (10/100/1000) enhances and standardizes network connectivity. Two link ports are available to cascade to up to 32 PDUs, with a network port sharing (NPS) feature to enable power sharing between Rack PDUs in the cascading group. Track or bill power usage confidently with 1% metering accuracy. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs have the following certifications: UL, CE, CSA, UKCA, Nemiko, PSE, KC, China RoHS, RCM, and CMIM. This model’s input power cord is 5125P6W and features 24 count C13/C15 and 24 count C13/C15/C19/C21 outlets. A 9.8 foot (3 meter) input cord makes it easier for the PDU to reach the power supply.